Pemuatan listrik bipolar untuk partikel aerosol
DOI:
https://doi.org/10.5614/jtki.2005.4.3.4Abstract
Bipolar diffusion charging of aerosol particles has been studied theoretically using Fuchs theory. Experimental data measured by several researchers available in the published literature were used to verify the calculation results. The calculation results show that Fuchs theory has been successfully used to predict the experimental data of the charging probability of submicron aerosol particles. The combination probability of ion-particle increases with the increase of particle size, both for particle and ion with the same sign and those with the opposite sign. However the combination probability is larger if the charges of particle and ion are of the opposite sign. Generally, Fuchs theory is not too easy to deal with due to the ill-defined of all parameters used, namely ion mass and ion mobility. These cause many possibilities of parameter combination that can give a good agreement with experimental data. Thus, in order to interpret the experimental results properly, the two parameters should be measured simultaneously with aerosol measurements.
Keywords: Aerosol, Bipolar Charging, Combination Probability
Abstrak
Pemuatan listrik difusi bipolar partikel aerosol telah dipelajari secara teoritis menggunakan teori Fuchs. Sebagai verifikasi digunakan data eksperimen beberapa peneliti yang tersedia dalam literatur yang telah dipublikasikan. Hasil perhitungan menunjukkan bahwa teori Fuchs berhasil memprediksi dengan baik data eksperimen probabilitas pemuatan listrik partikel aerosol dalam rentang ukuran partikel berukuran submikron. Probabilitas penggabungan ion-partikel semakin besar dengan semakin besarnya ukuran partikel, baik untuk partikel dan ion yang memiliki tanda yang berlawanan maupun yang memiliki tanda yang sama. Akan tetapi, probabilitas penggabungan untuk partikel dan ion yang memiliki tanda yang berlawanan memiliki nilai yang lebih besar. Pada umumnya teori Fuchs tidak terlalu mudah untuk digunakan yang disebabkan oleh tidak terdefinisikannya dengan baik semua parameter yang digunakan, yaitu massa ion dan mobilitas ion. Hal ini mengakibatkan banyak kemungkinan kombinasi parameter yang bisa menghasilkan kesesuaian yang bagus dengan data hasil pengukuran. Jadi, agar dapat menginterpretasikan hasil pengukuran dengan tepat, kedua besaran tersebut harus diukur secara serempak denganpengukuran aerosol.
Kata Kunci: Aerosol, Pemuatan Listrik Bipolar, Probabilitas Penggabungan
References
Bricard, J., Cabane, M., Madelaine, G. dan Vigla, D. (1972), "Formation and Properties of Neutral Ultrafine Aerosol Particles and Small Ions Conditioned by Gaseous Impurities of the Air", J. Colloid lnte1face Sci., 39, hal. 42-58
Friedlander, S. K., (2000), "Smoke, Dust and Haze: Fundamentals of Aerosol Dynamics", edisi 2, Oxford University Press, Oxford, hal.40-46
Fuchs, N. A. (1963), "On The Stationary Charge Distribution on Aerosol Particles in a Bipolar Ionic Atmosphere", Geophys. Pure Appl., 56, hal. 185-193
Kodas, T. T. dan Hampden-Smith, M. J.(1999), "Aerosol Processing of Materials", Wiley-VCH, New York, hal. 55-62
Marlow, W. H. dan Brock, J. R. (1975), "Calculations of Bipolar Charging of Aerosols", J. Colloid Interface Sci., 51, hal. 23-31
Matsuokas dan Friedlander ( 1991), "Dynamics of Aerosol Agglomerate Formation", J. Colloid Interface Sci., 146, hal. 495-506
Natanson, G. L. (1960), "On The Theory of Charging of a Microscopic Aerosol Particles by Aerosol Photoemission (APE)", Sov. Phys. Tech. Phys., 5, hal. 538-551
Press, W. H., Teukolsky, S. A., Vetterling, W. T. dan Flannery, B. P., (1992), "Numerical Recipes in Fortran 77", edisi 2, Cambridge University Press, New York, hal. 134-135 & hal. 390-395
Reischl, G. P., Makela, J. M., Karch, R. dan Necid, J., (1996), "Bipolar charging of ultrafine particles in the size range below I 0 nm",J. Aerosol Sci.,27, hal. 931-949
Shimada, M., Cho, S. J., Okuyama, K., Tamura, T., Adachi, M. Dan Fujii, T., (1997), "Removal of Airborne Particles by a Tubular Particle-removal Device using UV/photoelectron Method", J. Aerosol Sci., 28, hal. 649-661
Shimada, M., Okuyama, K., Inoue, Y., Adachi, M. dan Fujii, T., (1999), "Removalof Airborne Particles by a Device Using uv/photoelectron Method under Reduced Pressure Conditions", J. Aerosol Sci., 30, hal. 341-353
Wiedensohler, A., (1988), "An Approximation of The Bipolar Charge Distribution for Particles in The Submicron Size Range", J. Aerosol Sci., 19, hal. 387- 389